Baylor Scott & White specimen packaging & transport guide

Baylor Scott & White publishes a reference-lab specimen collection manual with test-specific collection, storage and transport instructions through its Pathology and Laboratory Medicine referral pages. Use that manual for test-level details; this page covers general packaging best practice. Confirm test-specific temperature and stability rules with the lab before pickup.

Independent guide · Not affiliated with Baylor Scott & White · Updated 2026-10-31

Lab-specific requirements

We could not verify Baylor Scott & White-specific packaging details from public documentation, so we do not list any here. Use the general steps below and confirm container, temperature, stability and pickup requirements directly with Baylor Scott & White using the official link(s) below.

Official Baylor Scott & White resources

Diagram of triple packaging for lab specimens: leak-proof primary tube, secondary biohazard bag with absorbent pad, rigid outer box marked UN3373
Triple packaging: primary receptacle, leak-proof secondary bag with absorbent, and rigid outer packaging.

General packaging steps

  1. Primary receptacle. Use the container the test requires, check the expiration date, tighten caps fully, and label with at least two patient identifiers plus collection date and time.
  2. Requisition. Match the order to the label exactly and place it in the bag's separate rear pocket so it stays dry.
  3. Secondary bag. Seal specimens in a leak-proof biohazard bag with enough absorbent for all the liquid; keep fragile tubes from touching.
  4. Temperature. One temperature per bag; follow the lab's ranges for ambient, refrigerated and frozen.
  5. Outer container. Use a rigid, insulated container; mark UN3373 for Category B shipments and follow dry-ice rules when used.
  6. Handoff. Count bags with the courier, note the time and temperatures, and keep your copy of the manifest.
Two-pocket specimen transport bag with tubes in the sealed front pouch and folded test requisition in the rear pocket with barcode showing
Step 2: specimens in the sealed front pouch, requisition folded in the rear pocket so paperwork stays dry.
Three specimen bags separated by temperature: ambient room temperature, refrigerated and frozen
Step 5: never mix temperatures in one bag. Each lab publishes its own temperature ranges.

Central Texas summers bring long stretches of high heat and occasional winter freezes, so insulated transport containers matter year-round on Austin-area routes. Keep pickup windows short and separate temperatures carefully.

Courier pickup checklist for lab specimens: caps tight, requisition in rear pocket, one patient per bag, temperatures separated
Step 10: a quick pickup checklist before the specimen leaves your office.

For the full walkthrough — including dry ice, 95 kPa bags, UN3373 vs. Category A, chain of custody and stability — read our complete specimen packaging and transport guide, and see the CDC, DOT, IATA and OSHA resources.

Frequently asked questions

How do I package a specimen for Baylor Scott & White?
Use triple packaging (labeled, tightly capped primary receptacle; leak-proof secondary bag with absorbent; rigid outer container), keep the requisition in the bag's separate pocket, separate temperatures, and confirm test-specific requirements with Baylor Scott & White.
Is Progressive Couriers affiliated with Baylor Scott & White?
No. Progressive Couriers is an independent courier and is not affiliated with, endorsed by, or an approved courier for Baylor Scott & White. This guide is informational.
Where does Progressive Couriers deliver specimens?
In the Phoenix metro and Arizona, and in the Austin, TX area. We transport ordinary clinical specimens, including Category B and exempt specimens, and do not accept Category A infectious substances.

Lab specimen transport requirements: packaging, temperature & chain of custody →

OSHA bloodborne pathogens & specimen transport requirements →

Not medical, legal or regulatory advice. This guide is general information last reviewed 2026-10-31. Requirements change; always follow the receiving laboratory's current test directory and instructions, and current DOT, IATA and OSHA rules. Illustrations are original diagrams for general education.

Questions? 602-499-2672